RééDOC
75 Boulevard Lobau
54042 NANCY cedex

Christelle Grandidier Documentaliste
03 83 52 67 64


F Nous contacter

0

Article

--";3! O
     

-A +A

Reliability, precision, and clinically important change of the Nine-Hole Peg Test in individuals with multiple sclerosis

HERVAULT M; BALTO JM; HUBBARD EA; MOTL RW
INT J REHABIL RES , 2017, vol. 40, n° 1, p. 91-93
Doc n°: 181933
Localisation : Documentation IRR

D.O.I. : http://dx.doi.org/DOI:10.1097/MRR.0000000000000209
Descripteurs : AE3 - SEP

This study evaluated the reliability, precision, and clinically important change
of the Nine-Hole Peg Test
(9-HPT) over a 1-week period.
Sixty-nine patients with
multiple sclerosis completed the 9-HPT on two occasions 1 week apart. Test-retest
reliability was based on intraclass correlation coefficient, and precision was
based on standard error of measurement and coefficient of variation. Clinically
important change was based on the minimal detectable change. Intraclass
correlation coefficients exceed 0.90 for all 9-HPT metrics. Standard error of
measurements for dominant (DH) and nondominant (NDH) hand time were 1.58 and 2.69
s, and 0.03 peg/s for both DH and nondominant NDH speed, respectively.
Coefficient of variations for DH and NDH time were 4.3 and 3.8%, and 4.5 and 4.6%
for DH and NDH speed. Minimal detectable changes for DH and NDH time were 19.4
and 29.1%, and 18.6 and 20.5% for DH and NDH speed.
These data provide evidence
on reliability, precision, and clinically important change of the 9-HPT over a
1-week period in multiple sclerosis for clinicians and researchers.