Mechanism of fluctuation in shear force applied to buttocks during reclining of back support on wheelchair

KOBARA K; FUJITA A; OSAKA H; ITO T; YOSHIMURA Y; ISHIDA H; WATANABE S
DISABIL REHABIL ASSIST TECHNOL , 2013, vol. 8, n° 3, p. 220-224
Doc n°: 163181
Localisation : Documentation IRR

D.O.I. : http://dx.doi.org/DOI:10.3109/17483107.2012.713434
Descripteurs : KF6 - FAUTEUIL ROULANT

The purpose of this study was to investigate the mechanism of the
fluctuation in the shear force applied to the buttocks. METHOD: The subjects were
11 healthy adult men without leg or trunk diseases.
The amount of force applied
to the buttocks was measured by using a force plate, and a pressure and shear
force sensor was used to measure the timing of the force applied to the back support. RESULTS: The average value of the shear force applied to the buttocks
was 9.4 +/- 2.4 (%BW) in the initial upright position (IUP), 9.3 +/- 1.2 (%BW) in
the fully reclined position (FRP), and 15.0 +/- 2.9 (%BW) in the returning to an
upright position (RUP). Significant differences appeared between the RUP and the
other positions. CONCLUSIONS: The results of this study suggested that the
adjustment of the axes of rotation of the back support and trunk-pelvis and the
release of the remaining shear force after the back support is reclined are
important for the prevention of decubitus ulcers.